Add a line on the graph

5 次查看(过去 30 天)
How can I add the red line following the bar shape on the graph? (like below image)
The code is:
num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
Electricity_Cost_values = 0.255; %EUR/kWh
FLH = 4380;
LHV = 33.33; %kWh/kgH2
%SOEC parameters
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 1142.7;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
%CAPEX_Stack_SOEC_values = 0.5*CAPEX_System_SOEC_values; % 50% of CAPEX system
CAPEX_SOEC_values = CAPEX_System_SOEC_values;
OPEX_SOEC_values = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean = 0.775;
System_Efficiency_SOEC_std = 0.0408;
System_Efficiency_SOEC_values = normrnd(System_Efficiency_SOEC_mean, System_Efficiency_SOEC_std, [num_simulations,1]);
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values < 0.74) = 0.74;
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values > 0.81) = 0.81;
%PEM parameters
CAPEX_System_PEM_mean = 1450; %$/kW
CAPEX_System_PEM_std = 367.42;
CAPEX_System_PEM_values = normrnd(CAPEX_System_PEM_mean, CAPEX_System_PEM_std, [num_simulations,1]);
CAPEX_System_PEM_values(CAPEX_System_PEM_values < 1100) = 1100;
CAPEX_System_PEM_values(CAPEX_System_PEM_values > 1800) = 1800;
%CAPEX_Stack_PEM_values = 0.35*CAPEX_System_PEM_values; % 35% of CAPEX system
CAPEX_PEM_values = CAPEX_System_PEM_values;
OPEX_PEM_values = 3;
System_Efficiency_PEM_mean = 0.58;
System_Efficiency_PEM_std = 0.0163;
System_Efficiency_PEM_values = normrnd(System_Efficiency_PEM_mean, System_Efficiency_PEM_std, [num_simulations,1]);
System_Efficiency_PEM_values(System_Efficiency_PEM_values < 0.56) = 0.56;
System_Efficiency_PEM_values(System_Efficiency_PEM_values > 0.6) = 0.6;
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 387.3;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
%CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = CAPEX_System_AEC_values;
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.0271;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate SOEC LCOH values
term1_S = LHV ./ System_Efficiency_SOEC_values;
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_SOEC_values / 100);
term4_S = CAPEX_SOEC_values ./ FLH;
LCOH_SOEC = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + Electricity_Cost_values);
% Calculate PEM LCOH values
term1_P = LHV ./ System_Efficiency_PEM_values;
term2_P = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P = (OPEX_PEM_values / 100);
term4_P = CAPEX_PEM_values ./ FLH;
LCOH_PEM = term1_P .* ((term2_P ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P) .* term4_P + Electricity_Cost_values);
% Calculate AEC LCOH values
term1_A = LHV ./ System_Efficiency_AEC_values;
term2_A = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A = (OPEX_AEC_values / 100);
term4_A = CAPEX_AEC_values ./ FLH;
LCOH_AEC = term1_A .* ((term2_A ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A) .* term4_A + Electricity_Cost_values);
% Create histograms for SOEC, AEC, and PEM LCOH values
figure;
% SOEC LCOH
subplot(3, 1, 1);
histogram(LCOH_SOEC, 'Normalization', 'probability', 'EdgeColor', 'w');
xlabel('LCOH (per kWh)');
ylabel('Probability');
title('SOEC LCOH Distribution');
ylim([0, 0.1]);
% AEC LCOH
subplot(3, 1, 2);
histogram(LCOH_AEC, 'Normalization', 'probability', 'EdgeColor', 'w');
xlabel('LCOH (per kWh)');
ylabel('Probability');
title('AEC LCOH Distribution');
ylim([0, 0.1]);
% PEM LCOH
subplot(3, 1, 3);
histogram(LCOH_PEM, 'Normalization', 'probability', 'EdgeColor', 'w');
xlabel('LCOH (per kWh)');
ylabel('Probability');
title('PEM LCOH Distribution');
ylim([0, 0.1]);
% Adjust layout
sgtitle('Monte Carlo Simulation Results for SOEC, AEC, and PEM');
% Show the plot
  1 个评论
Dyuman Joshi
Dyuman Joshi 2024-1-16
Should be easy to do with plot.
What seems to be the problem?
What does the red line denote?

请先登录,再进行评论。

采纳的回答

Star Strider
Star Strider 2024-1-16
编辑:Star Strider 2024-1-17
Try this —
num_simulations = 10000;
%Common parameters
Discount_Rate_min = 0.06; % assume 6-8%
Discount_Rate_max = 0.08;
Discount_Rate_values = unifrnd(Discount_Rate_min, Discount_Rate_max, [num_simulations, 1]);
Lifetime = 20; % years
Electricity_Cost_values = 0.255; %EUR/kWh
FLH = 4380;
LHV = 33.33; %kWh/kgH2
%SOEC parameters
CAPEX_System_SOEC_mean = 4200; %$/kW
CAPEX_System_SOEC_std = 1142.7;
CAPEX_System_SOEC_values = normrnd(CAPEX_System_SOEC_mean, CAPEX_System_SOEC_std, [num_simulations,1]);
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values < 2800) = 2800;
CAPEX_System_SOEC_values(CAPEX_System_SOEC_values > 5600) = 5600;
%CAPEX_Stack_SOEC_values = 0.5*CAPEX_System_SOEC_values; % 50% of CAPEX system
CAPEX_SOEC_values = CAPEX_System_SOEC_values;
OPEX_SOEC_values = 3; % 3% of CAPEX/a
System_Efficiency_SOEC_mean = 0.775;
System_Efficiency_SOEC_std = 0.0408;
System_Efficiency_SOEC_values = normrnd(System_Efficiency_SOEC_mean, System_Efficiency_SOEC_std, [num_simulations,1]);
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values < 0.74) = 0.74;
System_Efficiency_SOEC_values(System_Efficiency_SOEC_values > 0.81) = 0.81;
%PEM parameters
CAPEX_System_PEM_mean = 1450; %$/kW
CAPEX_System_PEM_std = 367.42;
CAPEX_System_PEM_values = normrnd(CAPEX_System_PEM_mean, CAPEX_System_PEM_std, [num_simulations,1]);
CAPEX_System_PEM_values(CAPEX_System_PEM_values < 1100) = 1100;
CAPEX_System_PEM_values(CAPEX_System_PEM_values > 1800) = 1800;
%CAPEX_Stack_PEM_values = 0.35*CAPEX_System_PEM_values; % 35% of CAPEX system
CAPEX_PEM_values = CAPEX_System_PEM_values;
OPEX_PEM_values = 3;
System_Efficiency_PEM_mean = 0.58;
System_Efficiency_PEM_std = 0.0163;
System_Efficiency_PEM_values = normrnd(System_Efficiency_PEM_mean, System_Efficiency_PEM_std, [num_simulations,1]);
System_Efficiency_PEM_values(System_Efficiency_PEM_values < 0.56) = 0.56;
System_Efficiency_PEM_values(System_Efficiency_PEM_values > 0.6) = 0.6;
%AEC parameters
CAPEX_System_AEC_mean = 950; % $/kW
CAPEX_System_AEC_std = 387.3;
CAPEX_System_AEC_values = normrnd(CAPEX_System_AEC_mean, CAPEX_System_AEC_std, [num_simulations,1]);
CAPEX_System_AEC_values(CAPEX_System_AEC_values < 500) = 500;
CAPEX_System_AEC_values(CAPEX_System_AEC_values > 1400) = 1400;
%CAPEX_Stack_AEC_values = 0.35*CAPEX_System_AEC_values; % 35% of CAPEX system
CAPEX_AEC_values = CAPEX_System_AEC_values;
OPEX_AEC_values = 3;
System_Efficiency_AEC_mean = 0.665;
System_Efficiency_AEC_std = 0.0271;
System_Efficiency_AEC_values = normrnd(System_Efficiency_AEC_mean, System_Efficiency_AEC_std, [num_simulations,1]);
System_Efficiency_AEC_values(System_Efficiency_AEC_values < 0.63) = 0.63;
System_Efficiency_AEC_values(System_Efficiency_AEC_values > 0.7) = 0.7;
% Calculate SOEC LCOH values
term1_S = LHV ./ System_Efficiency_SOEC_values;
term2_S = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_S = (OPEX_SOEC_values / 100);
term4_S = CAPEX_SOEC_values ./ FLH;
LCOH_SOEC = term1_S .* ((term2_S ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_S) .* term4_S + Electricity_Cost_values);
% Calculate PEM LCOH values
term1_P = LHV ./ System_Efficiency_PEM_values;
term2_P = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_P = (OPEX_PEM_values / 100);
term4_P = CAPEX_PEM_values ./ FLH;
LCOH_PEM = term1_P .* ((term2_P ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_P) .* term4_P + Electricity_Cost_values);
% Calculate AEC LCOH values
term1_A = LHV ./ System_Efficiency_AEC_values;
term2_A = Discount_Rate_values .* (1 + Discount_Rate_values).^Lifetime;
term3_A = (OPEX_AEC_values / 100);
term4_A = CAPEX_AEC_values ./ FLH;
LCOH_AEC = term1_A .* ((term2_A ./ ((1 + Discount_Rate_values).^Lifetime - 1) + term3_A) .* term4_A + Electricity_Cost_values);
% Create histograms for SOEC, AEC, and PEM LCOH values
figure;
% SOEC LCOH
subplot(3, 1, 1);
histogram(LCOH_SOEC, 'Normalization', 'probability', 'EdgeColor', 'w');
Ax1 = gca;
drawRedLine(Ax1);
xlabel('LCOH (per kWh)');
ylabel('Probability');
title('SOEC LCOH Distribution');
ylim([0, 0.1]);
% AEC LCOH
subplot(3, 1, 2);
histogram(LCOH_AEC, 'Normalization', 'probability', 'EdgeColor', 'w');
Ax2 = gca;
drawRedLine(Ax2);
xlabel('LCOH (per kWh)');
ylabel('Probability');
title('AEC LCOH Distribution');
ylim([0, 0.1]);
% PEM LCOH
subplot(3, 1, 3);
histogram(LCOH_PEM, 'Normalization', 'probability', 'EdgeColor', 'w');
Ax3 = gca;
drawRedLine(Ax3);
xlabel('LCOH (per kWh)');
ylabel('Probability');
title('PEM LCOH Distribution');
ylim([0, 0.1]);
% Adjust layout
sgtitle('Monte Carlo Simulation Results for SOEC, AEC, and PEM');
% Show the plot
% function drawRedLine(axh)
% % Draws the red line in each histogram subplot.
% H = axh.Children;
% BinCtrs = H.BinEdges(1:end-1)+diff(H.BinEdges)/2;
% B = polyfit(BinCtrs,H.Values,2) ;
% RedLine = polyval(B, BinCtrs);
% FudgeFactor = max(H.Values) - max(RedLine);
% hold on
% plot(axh,BinCtrs, RedLine + FudgeFactor, '-r', 'LineWidth',1)
% hold off
% end
function drawRedLine(axh)
% Draws the red line in each histogram subplot.
H = axh.Children;
BinCtrs = H.BinEdges(1:end-1)+diff(H.BinEdges)/2;
Data = H.Values;
u = mean(BinCtrs);
s = std(Data);
ndpdf = @(b,x) b(1) .* exp(-(x-b(2)).^2 ./ b(3));
B = fminsearch(@(b)norm(Data-ndpdf(b,BinCtrs)), [max(H.Values); u; s]);
% text(axh, B(2), max(H.Values), sprintf('$p(x) = %.3fe^{-\\frac{(%.2f-x)^2}{%.3f}}$', B), 'Horiz','center','Vert','bottom','Interpreter','latex')
RedLine = ndpdf(B, H.BinEdges);
hold on
plot(axh,H.BinEdges, RedLine, '-r', 'LineWidth',1.5)
hold off
end
EDIT — (17 Jan 2024 at 04:57)
It occurred to me later that the red line could be a normal probability distribution, although exactly what it is has not yet been divulged. If so, my new ‘drawRedLine’ function may be correct. (The previous one was just a guess.) The distribution parameters are the ‘B’ vector, whose contents are not shown here, however would be readily available. I provided a text call that presents them (commented-out) in case that information is desired.
.
  10 个评论
Minhee
Minhee 2024-1-24
Thank you so much.
Finally I got the graph!!
Star Strider
Star Strider 2024-1-24
As always, my pleasure!

请先登录,再进行评论。

更多回答(1 个)

Hassaan
Hassaan 2024-1-16
编辑:Hassaan 2024-1-16
此 个回答 已被 Adam Danz 标记
% Assuming 'LCOH_SOEC' is the array containing your SOEC LCOH data
% and you've already created a histogram:
histogram(LCOH_SOEC, 'Normalization', 'probability', 'EdgeColor', 'w');
hold on; % Retain the current plot
% Now, let's say you want to add a vertical line at the mean value of the LCOH
mean_value = mean(LCOH_SOEC);
y_limits = ylim; % Gets the current limits of the y-axis
% Plot a vertical line at the mean value
plot([mean_value mean_value], y_limits, 'r-', 'LineWidth', 2);
hold off; % Release the plot
This script will add a vertical red line at the mean value of the SOEC LCOH data on the histogram. If you want to add other types of lines (horizontal, or at a specific x or y value), you would adjust the plot command accordingly.
-----------------------------------------------------------------------------------------------------------------------------------------------------
If you find the solution helpful and it resolves your issue, it would be greatly appreciated if you could accept the answer. Also, leaving an upvote and a comment are also wonderful ways to provide feedback.
Professional Interests
  • Technical Services and Consulting
  • Embedded Systems | Firmware Developement | Simulations
  • Electrical and Electronics Engineering
It's important to note that the advice and code are based on limited information and meant for educational purposes. Users should verify and adapt the code to their specific needs, ensuring compatibility and adherence to ethical standards.
Feel free to contact me.
  2 个评论
Adam Danz
Adam Danz 2024-1-16
> Now, let's say you want to add a vertical line at the mean value of the LCOH
This answer is not helpful. The OP is not asking how to create vertical lines and the red lines in the OP's question are obviously not based on means.
@Muhammad Hassaan Shah please review the Generative AI guidelines for MATLAB Central
The use of generative AI tools is allowed but you are responsible for ensuring that your content is relevant and accurate.
Hassaan
Hassaan 2024-1-16
编辑:Hassaan 2024-1-16
@Adam Danz Just for my understanding:
  • Can you please elaborate how is it 'generative AI' if my understanding is incorrect for such case and the solution is not as per the requirements.
  • There are a millions ways to tackle a problem and OP may or may not agree with the solution. How this falls under 'not helpful' or 'generative AI' or flagged as?
  • What are the metrics to be classified as a generative content?.
Thank you.

请先登录,再进行评论。

类别

Help CenterFile Exchange 中查找有关 Colormaps 的更多信息

标签

产品


版本

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by